Using the SNMP Monitor

The Simple Network Management Protocol (SNMP) is the protocol responsible for governing network management. In this monitor, WhatsUp Gold utilizes SNMP to gather specific information about the functions of SNMP-enabled network devices by querying a device to verify that it returns an expected value. Depending on the state you choose, the monitor is considered either Up or Down according to the returned value.

To configure an SNMP Monitor:

  1. Go to the Active Monitor Library:
    • From the web interface, click GO. The GO menu appears.
    • If the WhatsUp section is not visible, click WhatsUp. The WhatsUp section of the GO menu appears.
    • Select Configure > Active Monitor Library. The Active Monitor Library appears.

      - or -

      From the main menu of the console, select Configure > Active Monitor Library. The Active Monitor Library appears.

  2. In the Active Monitor Library, do one of the following:
    • Click New. The Select Active Monitor Type dialog appears.
    • Select SNMP Monitor from the list, then click OK. The Add SNMP Monitor dialog appears.

      - or -

    • Select an existing SNMP Monitor, then click Edit. The monitor properties dialog appears.
  3. Enter or select the appropriate information in the following fields.
    • Name. The name of the monitor as it appears in the Active Monitor Library.
    • Description. The description of the monitor as it appears in the Active Monitor Library.
    • Object ID. Click the Browse button; then, locate and select the appropriate SNMP object in the MIB object tree. For more information, see Selecting an Object in the MIB Tree below.
    • Check type. Select Constant Value, Range of Values, or Rate of Change in Value.

      Constant Value

      • Value. Depending on the Object ID you selected, enter the appropriate value.
      • If the value matches, then the monitor is: select Up or Down.

      Range of Values

      • Low Value. Depending on the Object ID you selected, enter the appropriate value.
      • High Value. Depending on the Object ID you selected, enter the appropriate value.

      Rate of Change in Value

      • Rate of Change (in variable units per second). Enter the desired value.
      • If the value is above the rate, then the monitor is: select Up or Down.
  4. Click OK to save changes.

See Also

Configuring active monitors

Using the Domain Name Service (DNS) Monitor

Using the NT Service Monitor

Using the Ping Monitor

Using the SSH Monitor

Using the TCP/IP Monitor

Using the Telnet Monitor

Using the Temperature Monitor

Using the WAP Radio Monitor

Using premium active monitors