IN THIS PAGE

What's New in Progress MOVEit Analytics 3.2.0

The Progress MOVEit Analytics 3.2.0 release focused on security vulnerabilities and customer issues to ensure that all security updates were applied to provide users with a secure and quality product.

To prevent potential vulnerabilities and resolve open CVEs, several third-party dependencies were updated. The updates include but are not limited to PostgreSQL and Tomcat which were updated to the latest version.

Fixed Issues

The following issues were fixed in Progress MOVEit Analytics 3.2.0.

ID

Category

Fixed Issue

66594

Security, Web App

The Tomcat default SSL cipher list was updated to remove less secure ciphers. To modify the SSL cipher settings, edit the Tomcat server.xml configuration file.

64098

Security, Web App

Apache Tomcat was updated to prevent a Request Smuggling vulnerability.

65654

Web App

The default Tomcat configuration was updated to suppress version and stack trace information on error pages. To modify this setting, edit the Tomcat server.xml configuration file.

Upgrading

Upgrading to the latest version of Progress MOVEit Analytics ensures that you have access to the latest features, fixes, security updates, and usability improvements.

Upgrade the Progress MOVEit Analytics Server first, then upgrade the Progress MOVEit Analytics Agent on each MOVEit database machine in your Progress MOVEit Analytics environment.

Note: If you have a support agreement, access to the latest version is included.

Get the Progress MOVEit Analytics Server and Agent Installers

  1. Log in to the Progress Community portal and select Product Downloads.
  2. Download the Progress MOVEit Analytics Server and Agent product packages.
  3. Before you run the upgrade installer.
    • Review Upgrade Considerations. They identify useful tips and guidelines for existing Progress MOVEit Analytics users.

Upgrade the Progress MOVEit Analytics Server

  1. Run the Progress MOVEit Analytics Server installer package. The upgrade process can take several minutes, depending on the size of your database.

    When you installed the previous version of Ipswitch Analytics, you provided Tomcat Logon Account information. The default was to use the local system account. If during that installation you specified a different account, the upgrade program prompts you for the username, password, and group of that account.

  2. When the upgrade is complete, log on to the Progress MOVEit Analytics Server and click Browse to License to upload your license file.

    Ipswitch Analytics 3.0 users do not need a new license for Progress MOVEit Analytics 3.2, the 3.0 license is valid.

Upgrade the Progress MOVEit Analytics Agent

Upgrade the Progress MOVEit Analytics Agent on each MOVEit database machine in your Progress MOVEit Analytics environment

  1. Run the Progress MOVEit Analytics Server installer package. The upgrade process can take several minutes.

Upgrade the Progress MOVEit Analytics Agent in Legacy Failover Environments

If you are using MOVEit Failover (Failover Manager), these instructions do not apply. For more information, see Failover 9.0 Documentation.

  1. Shut down the Progress MOVEit Analytics Agent service on the server machines that host the primary and secondary instances of MOVEit Automation.
  2. Upgrade the Progress MOVEit Analytics Agent on the primary instance of MOVEit Automation.
  3. Upgrade the Progress MOVEit Analytics Agent on the secondary instance of MOVEit Automation.

Upgrade Paths

Progress MOVEit Analytics 3.2.0 supports "direct upgrade" (upgrade by way of running the Progress MOVEit Analytics installer) for existing Ipswitch Analytics 2017 (2.0) and newer.

Use the Upgrade Path table below to determine the most efficient upgrade path from your current version to Progress MOVEit Analytics 3.2.0.

The Progress MOVEit Analytics installer checks your version number and prevents upgrades from versions earlier than 2017 (2.0).

Your version

Upgrade path

Ipswitch Analytics 2017 (2.0) or later

  1. Download Progress MOVEit Analytics 3.2.0 from the Progress Community.
  2. Your upgrade activation code is embedded in the installer file, and is automatically used during installation.

Ipswitch Analytics 1.1 or earlier

 

  1. Upgrade to a supported version, such as 2017 (2.0) using the 2017 installer in upgrade mode.
  2. Use the latest installer to upgrade to Progress MOVEit Analytics 3.2.0.

    If your product version is close to or past its sunset or retirement milestones, upgrade to the latest version of Progress MOVEit Analytics. For more information, see the Product Lifecycle page.

Upgrade Considerations

Latest features and improvements

For the most up-to-date information about the latest supported features and improvements, see What's New.

System Requirements

Review the current System Requirements.

Database and files backup

Back up your existing database. For instructions, see the PostgreSQL documentation.

Back up the following files:

  • cert files. These files are named server*.pem and are located in the install directory in apache-tomcat/certs
  • .init file. This file is located in the install directory in apache-tomcat/conf/.init

System Requirements

Progress MOVEit Analytics requires certain software and hardware to ensure correct operation.

Analytics Server Requirements

The Progress MOVEit Analytics Server must be installed on a dedicated physical or virtual machine. Do not install the Progress MOVEit Analytics Server on a machine that hosts a MOVEit server or a MOVEit database.

Hardware Requirements

System Size

(determined by the number of Agents. One agent per MOVEit server/SQL database)

Small

Medium

Large

# of Analytics Agents

5 or fewer

6 - 10

11 - 20

Minimum RAM1

8 GB

16 GB

32 GB

Free hard disk space2

1 TB

2 TB

4 TB

CPU

4 Core 2.2 GHz

4 Core 2.2 GHz

8 Core 2.2 GHz

Network Interface Card

Gigabit Ethernet. The Progress MOVEit Analytics Server machine must have network access to the Progress MOVEit Analytics Agent.

Disk Subsystem Performance

Minimum of 200 average IOPS

1 The amount of RAM required depends on the number of MOVEit servers and their estimated number of monthly transactions. The Progress MOVEit Analytics Server installer tunes the Progress MOVEit Analytics PostgreSQL database automatically based on the RAM detected during installation.

2 The amount of hard drive space required depends on the number of MOVEit servers and their estimated number of monthly transactions. Higher numbers of transactions and/or tasks might require a larger hard drive. A transaction includes uploads, downloads, and Central steps. If you are not sure of your MOVEit activity level, see Estimate Monthly Transactions. Recommended: 1 or 2 months after you install the Progress MOVEit Analytics server, check your system to verify that you have enough hard drive space to retain all of your data. Suggested: To improve overall data loading and reporting performance, consider using SSD drives instead of spinning drives.

Software Requirements

Supported Operating Systems

  • Windows Server 2022
  • Windows Server 2019
  • Windows Server 2016

Analytics Agent Requirements

Hardware Requirements

Minimum Progress MOVEit Analytics Agent Requirements

  • 512 MB RAM
  • 1 GB or larger free disk space

Network Connectivity

  • Network connectivity with the MOVEit database and the Progress MOVEit Analytics Server. The Agent machine does not need network connectivity with the MOVEit server.
  • Network connectivity for MS Exchange support. MS Exchange support requires an SSL connection between the Exchange server and the Progress MOVEit Analytics server.

Supported MOVEit Products

The Analytics Agent supports data ingestion from the following MOVEit products when they are configured to use MySQL or Microsoft SQL server.

  • MOVEit Transfer 2019.1 and later
  • MOVEit Automation 2019.1 and later

Web Browser and Additional Requirements

Supported Web Browsers

  • Chrome
  • Mozilla Firefox
  • Microsoft Edge
  • Safari

Other browsers may work with Progress MOVEit Analytics but are not supported.

Known Issues

This section details known issues and workarounds in Progress MOVEit Analytics 3.2.0.

ID

Category

Known Issue

UREP-5217

Agent-Install

The Agent's server version is displayed as "0" on the UI when the Progress MOVEit Analytics Agent is upgraded directly from version 2.0 to 2018 (3.0).

To workaround this issue, complete the following steps.

  1. Edit the value of "observing.system.version" in the agent.properties file to reflect the current version.

    The default location of the agent.properties file is in the C:\Program Files\Ipswitch\Analytics Agent\conf directory.

  2. Save and restart the agent.

Licensees and Evaluators

Read the end user license agreement (EULA) before installing or using this product: Progress End User License Agreement

Copyright Notice

Visit the following page online to see Progress Software Corporation’s current Product Documentation Copyright Notice/Trademark Legend: Product Documentation Copyright Notice & Trademarks | Progress

NOV