To access these additional fields: Select HOSTS and click the name of the AS2 host. You can filter the list.
Note: The host's properties page shows the configured settings for each property area. To view all possible settings, click Edit.
For General properties, see AS2 Host Field Descriptions.
AS2 Host Field |
Description |
---|---|
Firewall |
|
Type |
Type of firewall, acting as a proxy, with which MOVEit Automation communicates. Available firewall types: Tunnel, SOCKS4, SOCKS5. Default is None. For the firewall you select, provide the following:
|
Decryption |
|
Use Signing Certificate for Decryption |
Selected (default): The signing certificate configured in the My Organization section of the host properties is used to decrypt files that are received from the partner. Not selected: Click Set Cert and select a certificate to be used to decrypt files received from the partner. Choose a certificate that is different from the signing certificate. |
Proxy Server |
|
Proxy Type |
Type of proxy server with which MOVEit Automation communicates. Available proxy types: Default, Specific. Default is None. The HTTP/S proxy is different to the firewall proxy setup. Consult your networking team to discuss which is appropriate. |
Hostname/IP Address, Port |
Hostname/IP address and TCP Port of the proxy server. |
Username/Password |
Username/password for MOVEit Automation to use to authenticate to the proxy server. |
SSL Mode |
Whether and how MOVEit Automation uses SSL to communicate with the proxy server. Options: Auto (default), Always, Never, Tunnel. |
Email MDN |
|
AS1 Host to Receive Email MDNs |
To request asynchronous email MDNs, specify an existing AS1 host. The host's configuration options determine the parameters that are sent in the MDN request. |
SMTP Server to Send Email MDNs |
The SMTP server through which email MDNs are sent when requested by the partner. |
Email Address to Send Email MDNs From |
The email address that is listed as the From address in email MDNs that are sent to the partner. |
Retry |
|
Retry Count |
The number of times that a transfer (get or put) is retried before the MOVEit Automation software no longer attempts the transfer. Values: 0 - transfer is not retried after a failure. Default is 3. The value can be overridden by settings in individual tasks. |
Retry Timeout |
The number of seconds between retries of a transfer (get or put). Default is 30 seconds. The value can be overridden by settings in individual tasks. |
Miscellaneous |
|
MDN Poll Count |
The number of times MOVEit Automation polls the POP3 server for an MDN message from the partner, after an EDI data message has been sent to the partner. Default is 10. |
MDN Poll Timeout |
Number of seconds between MDN polls. Default is 30 seconds. |