MOVEit Transfer provides a series of server and system health checks. A health check that fails will trigger critical email notifications (to the Critical System Alerts address). You can define the Critical System Alert email recipients using the MOVEit Transfer Configuration Utility.
MOVEit Transfer system monitors for certain critical events or system check failures and notifies responsible individuals by way of the Key Email Address configuration (set in the Email tab of the MOVEit Transfer Configuration Utility).
System Check |
Triggers a Critical Event Notification when... |
||
Check Local Drives |
100% disk usage, disk write failure, or similar detected. |
||
Check Transfer Web Server |
IIS is out of threads, down, or not responding. |
||
Check for Disabled Encryption |
Encryption is turned off or not detected. |
||
Invalid Certificate |
Server-side SSH certificate is wrong, invalid, or expired. |
||
Default FTP Certificate Expired |
FTP cert used for FTPS is expired. |
||
No FTP Ports Configured |
No open FTP ports could be found (applies to both implicit and explicit modes). |
||
Database Services |
Database service down. |
||
Duplicate Port |
Port map duplication error. |