Configuring a Syslog threshold
To configure a Syslog threshold:
- From the WhatsUp Gold web interface, go to . The Alert Center Threshold Library dialog appears.
- Click . The Select Threshold Type dialog appears.
- Select , then click . The New Syslog Threshold dialog appears.
- Specify or select the appropriate information in the dialog box:
- . Specify a name for the threshold. This name helps you identify the threshold in the Threshold library and displays as the report title on the Alert Center Home page.
- . Select the Syslog monitor to use with the threshold. This list is populated with Syslog monitors currently configured in the Passive Monitor Library.
- . Select and enter the desired threshold criteria variables and values. The default threshold is configured to alert when the number of messages exceeds 500 in the past 60 minutes.
- . Click to choose the devices to which the threshold applies. By default, the threshold monitors all devices on which the applicable monitor is enabled.
- . Select the notification policy to apply to this threshold. This policy begins sending notifications when an item is outside the configured threshold limits. If you do not see an appropriate threshold policy, or if the list is empty, click browse (...) to open the Notification Policy dialog and configure a new policy.
: Notification policies are optional for most thresholds. If you do not select a notification policy, no notifications are generated for the threshold, but a dashboard report listing the out of threshold items still appears on the Alert Center Home page.
- . Enter a value for the threshold check interval, or the interval at which the Alert Center checks the WhatsUp Gold database to see if there are items that are outside the threshold parameters.
- Select to have Alert Center automatically resolve items when they go back inside the parameters of the threshold.
: Configure the threshold check interval for a longer time than the sampling interval for thresholds relating to trends, such as percent utilization. Configure it for a time the same as (or similar to) the sampling interval when configuring a threshold for a health check.
Avoid setting the threshold check interval to a very short time as this can degrade system performance. In general, setting the threshold check interval to less than five minutes is inadvisable.
- Click to save the threshold settings.