Example: monitoring router bandwidth

You can configure WhatsUp Gold to gather bandwidth usage on your SNMP enabled devices (routers, switches, etc.) and then track that usage through performance reports. For bandwidth monitoring, the Interface Utilization monitor is the most useful as it illustrates percent utilization and throughput.

The Interface Utilization monitor gathers statistics on the volume of bytes traveling to and from the active interfaces on a device. You can collect data on all interfaces, active interfaces, or specific interfaces. This monitor is configured and enabled through Device Properties > Performance Monitors.

Note: Before you can configure the monitor for a device, you must enable SNMP and assign the proper credentials via the Credentials Library. The Performance Monitoring system uses these credentials to connect to the device during the configuration process, and during normal performance gathering. For more information, see Enabling SNMP on Windows devices.

Configuring the monitor

The Interface Utilization Performance Monitor is one of the default performance monitors installed with WhatsUp Gold, and needs no global configuration to configure the monitor for a single device.

To configure the Bandwidth Monitor:

  1. Select Properties from the right-menu.
  2. Select Performance Monitors on the Device Properties dialog.
  3. Select the Interface Utilization monitor from the list.
  4. Click Configure to set up the monitor for the device. WhatsUp Gold scans the device and discovers the interfaces on the device.

    When the scan completes, the Configure Interface Data Collection dialog appears. If the credentials for the device are not configured properly, the scan will fail (return to the Credentials Library to fix it). If the device is not SNMP-enabled, the scan will fail.

  5. Select the interfaces you want to collect data for. From the Collect data for pull-down, select All, Active, or Specific. If you select Specific, select just the interfaces you want to monitor in the list below. By default, active interfaces will be measured.
  6. (Optional) Click Advanced to change the retry and timeout settings for the SNMP connection to the device. Click OK to save the changes to the Advanced Settings.
  7. On the Configure Interface Data Collection dialog, enter a time interval (in minutes) for how long you want the application to wait between polls. The default is 10 minutes. See, "ProOptions - Report Data for more information on data collection and roll-up."
  8. Click OK to save the Interface Utilization configuration.

Viewing the data

WhatsUp Gold will take several polling cycles to produce meaningful graphs (with a 10 minute poll interval, this may mean a few hours). After enough data is gathered, several reports display this data.