Settings specific to WhatsUp Gold Distributed Edition must be configured in both the web interface and in the Admin Console application.
On the central WhatsUp Gold installation, launch the Admin Console application from the Windows Start menu, then select Configure > Program Options > Central Site Configuration. First, enable Allow Remote Site connections to this Central Site to access additional configuration settings. Next, enter the TCP Port, User Name, and Password specified during Remote Site installation. If desired, modify the Polling Interval and/or indicate specific hosts which the Central Site will allow or deny remote site connections. Then, click OK.
On the remote WhatsUp Gold installation, launch the Admin Console application from the Windows Start menu, then select Configure > Program Options > Remote Site Configuration. First, enable Enable Remote Site reporting to Central Site to access additional configuration settings. Next, enter the Central Site IP Address, login credentials, Remote Site display name, and HTTP address. Then, click OK.
On the central WhatsUp Gold installation, select SETTINGS > System Settings > Remote Site Configuration to launch the Remote Client Site Configuration dialog. This dialog displays a table of WhatsUp Gold instances configured as remote sites. In addition to the name of each remote site which is assigned during that site's installation, the dialog provides the IP address and the local device name. The local device is the remote site's device name as it appears in the central site's monitoring inventory. From here, you can select a remote site configuration and either edit () or remove () it from WhatsUp Gold. Please note, removing a remote site configuration using this dialog only removes the record from the central site installation of WhatsUp Gold. It does not uninstall WhatsUp Gold from the remote site. Additionally, if you remove a remote site configuration, any dashboard view containing reports with data for the remote site will need to be removed, then re-added to the dashboard to display data for that device.
When editing a remote site configuration, two controls are available:
To ensure a secure connection when communicating between central and remotes sites, we recommend using signed SSL certificates. Additionally, to successfully do so, you must configure remote site(s) NOT to ignore certificate errors. Completion of the following steps should allow for successful configuration of a signed SSL certificate:
Locate and run the NmDistributed.exe executable file which can be found in the same location where the WhatsUp Gold installer resides on the server. This launches a dialog where you can:
The NmDistributed service must be restarted for changes made within this dialog to take effect.