Enabling the SNMP Trap Listener
You must enable the SNMP Trap listener to collect data for the SNMP Trap Log report.
: The SNMP Trap Listener cannot be enabled through the web interface; it must be enabled in the WhatsUp Gold console.
: The Microsoft SNMP Trap Listener must be disabled to enable the WhatsUp Gold SNMP Trap Listener.
To enable the SNMP Trap listener:
- In the WhatsUp Gold console, select . The Program Options dialog appears.
- Select .
- Select , then click . The SNMP Trap Listener Configuration dialog opens.
- Select and enter a port number to enable the SNMP Trap Listener (default port is 162).
- To collect data on unsolicited events as well, select .
: Do not select this option when using SNMP v3 credentials.
- Click to close the SNMP Trap Listener Configuration dialog. Click again to close the Program Options dialog.
To disable the Microsoft SNMP Trap Listener:
- Click and type s
ervices.msc
in the search box. The Services console appears. - Locate in the list of services.
- Right-click and select from the menu.
- Verify that the service status is . If the service status is Started, click the button.
- Verify that the Startup type is or . If the startup type is set to another type, select from the Startup type menu.
- Click to close the SNMP Trap Properties dialog.