Enabling the Windows Event Log listener
You must enable the Windows Event Log listener to collect data for the Windows Event Log.
To configure the Windows Event Log Listener:
- From the WhatsUp Gold console main menu, select . The Program Options dialog appears.
: If the Windows SNMP Trap Service ( > ) is running on the WhatsUp Gold console PC, you should stop the service. This is a precaution to prevent any conflict with the WhatsUp Passive Monitor Listener.
- Click . The WhatsUp Gold Passive Monitor Listeners display in a list.
- Select the Windows Event Log Listener, then click . The Windows Event Log Listener Configuration dialog appears.
- Enter or select the appropriate information in the following fields:
- . Select this option if you would like WhatsUp Gold to listen for Windows Event logs.
- . Select this option to only add the event time and message to the Windows Event Log; the payload is withheld from the entry.
- . Select this option to have WhatsUp Gold check for and close inactive connections at the interval you specify. The default interval is 60 seconds.
- Click to save changes.