Configuring a failed connections threshold

To configure a Flow failed connections threshold:

  1. From the WhatsUp Gold web interface, go to Alert Center > Threshold Library. The Alert Center Threshold Library dialog appears.
  2. Click New. The Select Threshold Type dialog appears.
  3. Select Flow Monitor Failed Connections, then click OK. The New Flow Monitor Failed Connections Threshold dialog appears.
    The New Flow Monitor Failed Connections Threshold dialog
  4. Specify or select the appropriate information in the dialog box:
    • Name. Specify a name for the threshold. This name helps you identify the threshold in the Threshold library and displays as the report title on the Alert Center Home page.
    • Threshold. Select and enter the desired threshold criteria variables and values. The default threshold is exceeded when when a host has sent or received more than 1000 failed connections in the past 15 minutes.

    Note: WhatsUp Gold Flow Monitor can only find failed connections on sources that are not sending sampled data.

    • Traffic to monitor. Select the Flow Monitor source or interface from which to monitor traffic.
      When you select a source, traffic for all interfaces on the source is monitored. When you select an interface, only traffic for the selected interface is monitored.
      By default, the threshold is set to monitor traffic from all Flow Monitor sources.

    Note: Sources sending sampled data are not displayed as a selection option in the Traffic to monitor list because Flow Monitor cannot determine that traffic has failed on sampled data.

    • Hosts to monitor. Click Select to choose the hosts to which the threshold applies. By default, the threshold monitors all applicable hosts.
    • Notification. Select the notification policy to apply to this threshold. This policy begins sending notifications when an item is outside the configured threshold limits. If you do not see an appropriate threshold policy, or if the list is empty, click browse (...) to open the Notification Policy dialog and configure a new policy.

    Note: Notification policies are optional for most thresholds. If you do not select a notification policy, no notifications are generated for the threshold, but a dashboard report listing the out of threshold items still appears on the Alert Center Home page.

    • Threshold check. Enter a value for the threshold check interval, or the interval at which the Alert Center checks the WhatsUp Gold database to see if there are items that are outside the threshold parameters.
    • Select Automatically resolve items no longer out of threshold to have Alert Center automatically resolve items when they go back inside the parameters of the threshold.

    Note: Configure the threshold check interval for a longer time than the sampling interval for thresholds relating to trends, such as percent utilization. Configure it for a time the same as (or similar to) the sampling interval when configuring a threshold for a health check.

    Avoid setting the threshold check interval to a very short time as this can degrade system performance. In general, setting the threshold check interval to less than five minutes is inadvisable.

  5. Click OK to save the threshold.

See Also

Configuring Flow Monitor thresholds

Configuring Flow Monitor thresholds

Selecting Flow Monitor threshold hosts

Configuring a conversation partners threshold

Configuring a Flow Monitor custom threshold

Configuring a Flow Monitor Interface Traffic threshold

Configuring a top sender/receiver threshold