Adding and editing a SNMP Extended Active Monitor
This monitor utilizes SNMP to gather specific information about the functions of multiple OIDs by querying the group to verify they return a expected value and allows you to monitor all devices using SNMP. While the standard SNMP monitor checks a single OID against a single threshold, the SNMP Extended monitor checks multiple OIDs against multiple thresholds using an XML file and predefined values for each supported device type to determine if the monitor is considered either up or down according to the returned value.
To add a new SNMP active monitor:
- From the WhatsUp Gold web interface, go to . The Monitor Library dialog appears.
- Click the tab. The Active Monitor list appears.
- Click . The Select Active Monitor Type dialog appears.
- Select then click . The New SNMP Extended Monitor dialog appears.
- Enter the appropriate information in the following fields:
- . Enter a name for the active monitor. This name displays in the Active Monitor Library.
- . Enter a short description for the monitor. This description displays next to the monitor in the Active Monitor Library.
- Click to launch the Select Import File dialog.
- Select the desired .xml file from the list containing applicable OIDs to monitor.
- Click to return to the New SNMP Extended Monitor dialog. The Thresholds to monitor section of the dialog now displays the OIDs from the imported .xml file as parameters.
- Select any parameter displayed, then click to launch the Edit Threshold dialog.
- Select the request type for the monitor:
- . When monitoring for a specific value, determine when the monitor should the report the device as Down by specifying if the response is, , , or the entered or value.
- . When monitoring a range, enter the minimum and maximum values the response must fall within for the monitor to report the device as Down.
- . When monitoring for a range of change, determine when the monitor should the report the device as Down by specifying if the response is, , or the entered value in seconds.
- Click to return to the New SNMP Extended Monitor dialog.
- Enable monitoring for specific parameters by selecting the respective checkboxes.
- Click to launch the Advanced SNMP Active Monitor Properties dialog.
- Configure the following advanced options:
- . Enter the length of time WhatsUp Gold attempts to connect.
- . Enter the number of times WhatsUp Gold should attempt to connect.
- . Select this option to cause the monitor to automatically check for enabled OIDs on the device to which the monitor is applied based on the configuration.
- Click .